Tropical corticosteroid bioequivalence testing comparison of chromameter and visual data

dc.contributor.advisorSmith, Eric W
dc.contributor.authorDemana, Patrick Hulisani
dc.date.accessioned2026-03-04T14:38:11Z
dc.date.issued1998
dc.description.abstractThe major criticism of the human skin blanching assay is the subjective nature of grading the response. Recently the American FDA released a Guidance document for topical corticosteroid bioequi valence testing. The guidelines require the use of a chromameter as a reliable method to estimate skin blanching. The purpose of this study was to evaluate the recommendations of this document for appropriateness by comparing visual and chromameter data. The visually-assessed blanching assay methodology routinely practised in our laboratories was modified to comply with the specifications of the Guidance. The preliminary trial indicated that the training period that is required for a novice to be classified as an experienced observer is not a major problem. The major trend that emerged from the pilot study was that visual assessment was better than the chromameter. Longer dose durations were found to be more discriminatory than shorter durations. The visual data were best described by the sigmoid Emax model and the chromameter data were best described by the simple Emax model. The pivotal results indicated that the D2/Dj criterion to determine sample size of "acceptable blanchers" produced only few subjects suggesting that the validity of this criterion requires extensive investigations. The estimates of the Locke's confidence interval method were simiJar to those for the general simple formula. However, due to undefined parameters of the Locke's method in the Guidance, the validity of the Locke's method requires evaluation. The chromameter b-scale parameter was the least sensitive in estimating skin blanching whereas the a- and L-scale parameters produced similar results. Poor correlation between visual and chromameter was noted indicating that the visual method is still the best method.
dc.description.degreeMaster's thesis
dc.description.degreeMSc
dc.format.extent170 pages
dc.format.mimetypeapplication/pdf
dc.identifier.otherhttp://hdl.handle.net/10962/d1003233
dc.identifier.urihttps://researchrepository.ru.ac.za/handle/123456789/7408
dc.languageEnglish
dc.publisherRhodes University, Faculty of Pharmacy, Pharmacy
dc.rightsDemana, Patrick Hulisani
dc.subjectDermatopharmacology
dc.subjectDermatologic agents
dc.subjectSkin absorption
dc.titleTropical corticosteroid bioequivalence testing comparison of chromameter and visual data
dc.typeAcademic thesis

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Tropical_corticosteroid_bioequivalence_testing_com_vital_3755.pdf
Size:
6.43 MB
Format:
Adobe Portable Document Format